Breath carbon monoxide monitor: PDD-301/sco and PDD-301/rco

The device ensures the measurement of breath carbon monoxide concentration
It is inevitable in the smoking cessation program
  • Monitoring and follow up of breath carbon monoxide concentration
  • Side stream gas analysis for higher accuracy and shorter response time
  • Full flow and volume monitoring during CO analysis
  • CO concentration range: 0 - 100 ppm
  • Automatic zero setting and calibration
  • Combination with a full feature spirometer and/or rhinomanometer

The PinkFlow* flow-meter and the spirometer fully complies with the specifications and requirements of the Standardization of Lung Function Testing ATS/ERS Task force (European Respiratory Journal 2005)

Connecting to a laptop PC provides full portability in battery mode as well

Software system overview

  • Measurement modes
  • Measured parameters
  • Accessories
  • Technical data
  • Breath carbon monoxide concentration
  • Forced ex- and inspiration
  • Static vital capacity
  • Maximal voluntary ventilation

Whole list of Pulmonary Function Tests’ parameters

  Breath carbon monoxide monitor
CO ppm Breath CO concentration
%COHb Carboxyhemoglobin %
SVC Slow Vital Capacity
  Forced ex and inspiration
FVC Forced Vital Capacity
FEV*0.5 Forced Expiratory Volume in 0.5 second
FEV*1.0 Forced Expiratory Volume in 1.0 second
FEV*0.5/IVC Ration of FEV*0.5 and IVC in %
FEV*0.5/FVC Ration of FEV*0.5 and FVC in %
FEV*1.0/IVC Ration of FEV*1.0 and IVC in %
FEV*1.0/FVC Ration of FEV*1.0 and FVC in %
PEF Peak Expiratory Flow
FEF*25-75% Forced mid-Expiratory Flow rate
FEF*75% Forced Expiratory Flow at 75% lung volume
FEF*50% Forced Expiratory Flow at 50% lung volume
FEF*25% Forced Expiratory Flow at 25% lung volume
FET Forced Expiratory Time
MTT Mean Transit Time
FIVC Forced Inspiratory Vital Capacity
FIV*0.5 Forced Inspiratory Volume in 0.5 sec
FIV*1.0 Forced Inspiratory Volume in 1.0 sec
PIF Peak Inspiratory Flow rate
FIF*25-75% Forced mid-Inspiratory Flow rate
  Static vital capacity
IVC Inspiratory Vital Capacity
IRV Inspiratory Reserve Volume
ERV Expiratory Reserve Volume
TV Tidal Volume
SVC Slow Vital Capacity
  Maximal Voluntary Ventilation
MVV Maximal Voluntary Ventilation
MVV*f Maximal Voluntary Ventilation Frequency
 
Flow meter PinkFlow
Type PPF-18
Principle Symmetric and averaging Pitot tube
Flow range ±18 l/s
Accuracy ±2% or 50 ml, whichever is greater
Dead space 36 ml
Resistance 60 Pa/l/s @ 15 l/s
Accuracy of volume ±3 % or ±50 ml
Range of CO 0 - 100 ppm
CO analyzer Electro chemical cell
Size of PC interface Height: 55 mm
  Wide: 140 mm
  Long: 185 mm
Weight 400 g
Power supply USB port
 

 

 

 
Patient circuit   Breath CO measurement
 
Device with the PinkFlow flow meter   FVC measurement
   
    IVC measurement
   
    MVV measurement